products 产品列表

 Hysteresis Dynamometer, Loading Controller, Acquisition Instrument and Software
 Hits:16631 AddTime:2021/9/20 23:06:21

Overview

The hysteresis dynamometer is suitable of medium and small power motor testing.The torque changes is not affected by the speed,It can do full test from no load to the blockage.

According to different cooling methods, hysteresis dynamomenters are divided into four types;HZC type is divided into fan cooling and natural cooling;HZC-Q type is compressed air cooling; HZC-G type is blower cooling,HZC-Y type is water cooling.

Dedicated load controller can be selected to adjust loading torque,and the torque ,speed and power of the motor can be collected by TS-2000 torque speed power acquistion instrument. The hysteresis dynamometer's measurement accuracy can reach ±0.2% of full scale.

This kind of dynamometer is cost-effective,small size, easy to operate,and can be customized according to customer's requirements.

Model
Rated torque N•m
Rated power within 5 minutes(W)
Rated power(Continuous)(W)
Maximum speed
Cooling method
Fan/natural cooling
Add compressed air
Add blower
Fan/natural cooling
Add compressed air
Add blower
HZC fan/natural cooling type hyspteresis dynamometer
HZC-0.01
0.01
35
-
-
8
-
-
30000
Fan cooling
HZC-0.02

0.02

35
-
-
8
-
-
30000
HZC-0.03
0.03
50
-
-
12
-
-
30000
HZC-0.05
0.05
50
-
-
12
-
-
30000
HZC-0.1
0.1
90
-
-
25
-
-
25000
HZC-0.2
0.2
90
-
-
25
-
-
25000
HZC-0.3
0.3
250
-
-
65
-
-
25000
HZC-0.5
0.5
250
-
-
65
-
-
25000
HZC-1
1
400
-
-
80
-
-
25000
HZC-2
2
580
-
-
120
-
-
25000
HZC-3
3
700
-
-
150
-
-
25000
HZC-5
5
1000
-
-
200
-
-
25000
Natural cooling
HZC-6
6
1000
-
-
200
-
-
25000
HZC-Q compressed air cooling hysteresis dynamometer
HZC-0.1/Q
0.1
90
200
-
25
80
-
25000
Compressed air cooling
HZC-0.2/Q
0.2
90
200
-
25
80
-
25000
HZC-0.3/Q
0.3
250
400
-
65
120
-
25000
HZC-0.5/Q
0.5
250
400
-
65
120
-
25000
HZC-1/Q
1
400
800
-
80
350
-
25000
HZC-2/Q
2
580
1000
-
120
500
-
25000
HZC-3/Q
3
700
1300
-
150
800
-
25000
HZC-5/Q
5
1000
1500
-
200
1200
-
20000
HZC-6/Q
6
1100
1700
-
200
1200
-
20000
HZC-10/Q
10
1200
2000
-
200
1200
-
12000
HZC-12/Q
12
1300
2100
-
200
1300
-
11000
HZC-15/Q
15
1400
2200
-
200
1400
-
10000
HZC-24/Q
24
1600
2400
-
200
1600
-
8000
HZC-30/Q
30
1600
2400
-
200
1600
-
8000
HZC-40/Q
40
1900
3000
-
200
1200
-
4000
HZC-50/Q
50
1900
3000
-
200
1200
-
4000
HZC-100/Q
100
2200
3500
-
250
1200
-
3000
HZC-G blower cooling type hysteresis dynamometer
HZC-3/G
3
700
-
1500
150
-
900
25000
Blower cooling
HZC-5/G
5
1000
-
2000
200
-
1800
25000
HZC-6/G
6
1400
-
3200
300
-
2800
25000
HZC-10/G
10
1700
-
3500
700
-
3000
12000
HZC-15/G
15
2000
-
3800
900
-
3500
10000
HZC-30/G
30
3800
-
7000
1300
-
5500
7000

HZC Type(0.03-2N•m)Short plate hysteresis dynamometer dimension

Mobel
A
B
C
D
E
F
G
H
I
φJ(h6)
K
L
φM
N
O
HZC-0.03S
216
280
15
160
180
220
17
95
3.7
4
6
250
9
200
1.5
HZC-0.05S
216
280
15
160
180
220
17
95
4.5
5
8
250
9
200
2
HZC-0.1S
216
280
15
160
180
220
17
95
5.2
6
8
250
9
200
2
HZC-0.2S
216
280
15
160
180
220
17
95
5.2
6
8
250
9
200
2
HZC-0.3S
216
280
15
160
180
220
17
95
7.2
8
10
250
9
200
2
HZC-0.5S
216
280
15
160
180
220
17
95
7.2
8
10
250
9
200
2
HZC-1S
226
280
15
180
200
241
22
115
9
10
10
250
9
216
2
HZC-2S
226
280
15
180
200
241
22
115
11
12
12
250
9
216
3

HZC-L Type(0.01-2N•m)Long plate hysteresis dynamometer dimension

Model
A
B
C
D
E
F
G
H
I
φJ(h6)
K
L
φM
N
O
HZC-0.01L
216
249
15
160
180
432
14.5
80
2.7
3
3
200
9
400
1.5
HZC-0.02L
216
249
15
160
180
432
14.5
80
2.7
3
3
200
9
400
1.5
HZC-0.03L
216
249
15
160
180
432
17
80
3.7
4
6
200
9
400
1.5
HZC-0.05L
216
249
15
160
180
432
17
80
4.5
5
8
200
9
400
2
HZC-0.1L
216
249
15
160
180
432
17
80
5.2
6
8
200
9
400
2
HZC-0.2L
216
249
15
160
180
432
17
80
5.2
6
8
200
9
400
2
HZC-0.3L
216
249
15
160
180
432
17
80
7.2
6
8
200
9
400
2
HZC-0.5L
216
249
15
160
180
432
17
80
7.2
6
8
200
9
400
2
HZC-1L
226
249
15
180
200
500
22
100
9
10
10
225
9
483
2
HZC-2L
226
280
15
180
200
550
22
100
11
12
12
230
9
483
3


HZC Type(3-100N•m)hysteresis dynamometer dimension

Model A B C D E F G H I φJ(h6) K L φM N O b
HZC-3 254 280 20 242 120 318 31 170 14 15 10 160 9 288 3
HZC-5 284 310 20 282 130 380 30 200 16 17 10 250 9 350 3
HZC-6 254 280 20 242 120 400 31 170 14 15 10 250 9 362 3
HZC-10 356 432 30 370 120 457 53 260 28 25 330 400 10.5 358 5 8
HZC-12 356 432 30 370 120 457 53 260 28 25 30 400 10.5 358 5 8
HZC-24 356 432 35 370 132 584 53 260 28 25 30 400 10.5 485 5 8
HZC-30 356 432 35 370 132 584 53 265 28 25 30 400 10.5 485 5 8
HZC-40 465 550 45 480 150 720 53 305 28 25 30 500 13 660 5 8
HZC-50 465 550 45 480 150 720 53 305 28 25 30 500 13 660 5 8
HZC-100 545 700 45 480 150 850 53 305 33 30 30 640 13 750 5 8

All models of the HZC-Q series are identical in size to the corresponding HZC series. The only difference is that there is an additional air input port for connecting compressed air(see the red dotted line on the up).



All models of the HZC-G series are identical in size to the corresponding HZC series,the only difference is that there is an additional air input port for connecting the blower(see the red dotted line on the up)。


All models of HZC-Y water cooling hysteresis dynamometer are indentical in size to the corresponding  HZC series. The only difference is the addition of two cooling water input and output interface. Advantages: no noise, high power(see water cooling hysteresis brake specifications).

SC-1WB-36-3 Programmable load power

1、Power supply:AC220V,output DC-36V/0~3A

2、High precision,high resolution,low temperature drift, high stability(the whole machine temperature drift is less 50ppm,accuracy 0.1%,resolution V=10mV、l=1mA)

3、Programmable(MODBUS agreement,RS485 communication)

4、Set value storage function(can save the voltage and current value set at the last shutdown)

5、Dimension:185*85*120mm,weight:1250g

TS-2000 Torque speed power acquisiton instrument

Overall dimension:280*145*110(L*W*H)(mm)

Hole size(mm):271*93

TS-2000 torque speed power acquisiton instrument uses hysteresis brake or a magnetic powder brake as a damping load ,and use a tension and pressure sensor, photoelectric ( or magnetoelectric ) rotational speed sensor as a detection componment ,can colleect torque,speed  and power of the power machine. The instrument comes with a  display screen to display the measurement results ,and is equipped with a standard serial interface of RS485 (or RJ45 network interface ) to communicate with the computer.

Technical indicators
Accuracy of measurement
±0.05%F.S
Acquisition cycle
≥10ms
Output signa
±20mV
Output signa
rs485 communication
Torque,speed two relay output
Net interface
Ethernet RJ45 interface
Instrument power supply
AC220VAC±10%
TS-2000 Test software


Function: Display the real-time torque,speed and power data and waveform of TS-2000 torque speed power acquisition instrument, and generate curves and reports for saving and printing。

【Refresh】【Favorites】【Print】 【Close】
Previous:HZC Fan/Natural cooling hysteresis Next:HL-k Type hysteresis clutch Dimension